Gantry Sludge Suction Machine
Structure & Working Principle
The siphon-type gantry sludge suction machine consists of travelling bridge,
suction pipes, drain pipes, submersible sludge pump, drive assembly, electric
control cabinet, running rails, sliding cable assembly, etc.
Supported by four supporting points, the main truss strides across the horizontal sedimentation tank with steel rails laid on both tank sides. The gantry travels from one tank end to the opposite end while sucking sludge continuously. It automatically reverses upon stroke limit signal and completes sludge
suction on return trip to finish one full operation cycle.
Product Application
The Gantry Sludge Suction Machine is widely used for horizontal-flow sedimentation tanks in wastewater treatment plants and waterworks, to scrape and suck settled sludge from tank bottom to sludge suction outlets. It features compact structure and reliable operation, equipped with automatic control and overload protection system.
-Center single-side drive: adopted when track spacing ≤4m;
-Dual-end synchronous drive: adopted when track spacing>6m.
Features
-Truss-type frame greatly reduces self-weight compared with conventional structures. Hot-dip galvanizing anti-corrosion treatment ensures rust-proof performance within 5 years; all water-contact parts are made of 304
stainless steel for prolonged service life.
-Low maintenance workload, small matching drive power and low operating cost; optimized pump configuration
ensures stable and reliable running.
-Advanced drive structure effectively avoids running deviation at both ends of the gantry.
-Solid steel travelling wheels guarantee long service lifespan.
Operation Management
1.Home position is set at tank outlet end. Open drain valves of all suction pipes before startup, then travel toward
inlet end; auto return to original standby position after reaching inlet to finish one full suction cycle.
2.Pump-drain type: composed of pump, suction rake and suction pipelines. Sludge is pumped out via tank outlet
pipeline; startup/shutdown is triggered by travel limit switch. Limit positions of track bump stops shall be fixed
during installation.
3.Avoid long-term sludge accumulation inside tank; sludge will compact severely after 2 days’ settling. Stop equipment immediately once pipeline clogging occurs and restore smooth drainage. Full tank cleaning is required if
sludge accumulates over 4 days to prevent frame deformation caused by excessive sludge resistance.
4.Never operate the machine before ice thawing if the tank surface freezes in cold season.
5.Prevent hard sundries like brick fragments falling into tank to avoid damage to suction nozzles.
Installation Requirements
1.Four travelling wheels must stay on two parallel horizontal rails; all rails are laid on same horizontal plane.
2.Pre-embedded anchor plates are reserved on tank top at 1m interval with bolt & press plate for rail fixing.
3.Place gantry on rails after hoisting, calibrate horizontal dimension; fix cables via wire rope and install travel limit &
anti-drop baffles.
4.No-load test running ≥8 continuous hours after installation to inspect wheel derailment risk.
5.Mount sludge pump on travelling frame; install suction pipes downward from pump inlet with nozzle clearance
10~20mm above tank floor, all branch pipes converge to main outlet drain.
6.Fill water over pump head by 30mm before commissioning and inspect sludge draining condition after pump
startup.
Model Specification Table
1.Siphon Type Technical Specification Table
| GantrySpec | Drive Unit | No. of Si-phon Pipes | Max Inlet Sludge Concentration(mg/L) | Rail Type | Unit Weight (t) | |||||||||||
| Span (m) | Height (m) | Width (m) | Wheel-span (m) | Speed (m/min) | Drive Type | Power (kW) | Speed (r/min) | 1½" | 2" | 2½" | 3" | |||||
| 8 | 1.2 | 1 | 2 | 1.4 | Dual-side Synchronous | 2*0.55 | 1.27 | 8 | 500 | 1000 | 1700 | 2500 | 18# Light Rail | 5 | ||
| 10 | 1.2 | 1 | 2 | 8 | 400 | 750 | 1300 | 2000 | 5.5 | |||||||
| 12 | 1.2 | 1 | 2.3 | 10 | 350 | 750 | 1300 | 2000 | 6.3 | |||||||
| 14 | 1.4 | 1 | 2.3 | 2*0.75 | 10 | 350 | 600 | 1100 | 1700 | 24# Light Rail | 7.2 | |||||
| 16 | 1.6 | 1 | 2.55 | 12 | 350 | 600 | 1100 | 1700 | 7.6 | |||||||
| 18 | 2 | 1 | 2.55 | 12 | 300 | 540 | 1000 | 1500 | 8.1 | |||||||
| 20 | 2 | 1 | 2.85 | 14 | 300 | 540 | 1000 | 1500 | 8.7 | |||||||
2.Pump Suction Type Technical Specification Table
| GantrySpec | Drive Unit | No. of Si-phon Pipes | Max Inlet Sludge Concentration(mg/L) | Rail Type | Unit Weight (t) | |||||||||||
| Span (m) | Height (m) | Width (m) | Wheel-span (m) | Speed (m/min) | Drive Type | Power (kW) | Speed (r/min) | 1½" | 2" | 2½" | 3" | |||||
| 8 | 1.2 | 1 | 2 | 1.4 | Dual-side Synchronous | 2*0.55 | 1.27 | 8 | 500 | 1000 | 1700 | 2500 | 18# Light Rail | 5 | ||
| 10 | 1.2 | 1 | 2 | 8 | 400 | 750 | 1300 | 2000 | 5.5 | |||||||
| 12 | 1.2 | 1 | 2.3 | 10 | 350 | 750 | 1300 | 2000 | 6.3 | |||||||
| 14 | 1.4 | 1 | 2.3 | 2*0.75 | 10 | 350 | 600 | 1100 | 1700 | 24# Light Rail | 7.2 | |||||
| 16 | 1.6 | 1 | 2.55 | 12 | 350 | 600 | 1100 | 1700 | 7.6 | |||||||
| 18 | 2 | 1 | 2.55 | 12 | 300 | 540 | 1000 | 1500 | 8.1 | |||||||
| 20 | 2 | 1 | 2.85 | 14 | 300 | 540 | 1000 | 1500 | 8.7 | |||||||
Product Structural Diagram