FQJB Floating Submersible Mixe
Selection Considerations
Selecting a submersible mixer is a complex task, and the correct selection directly affects the equipment’s performance. The principle of selection is to ensure the mixer performs its full mixing function within a suitable volume, which is generally determined by flow velocity. Depending on the different process requirements of the wastewater treatment plant, the appropriate flow velocity for the mixer should be between 0.15 and 0.3 m/s. A flow velocity below 0.15 m/s will not achieve the desired mixing effect, while a flow velocity exceeding 0.3 m/s will negatively impact the process and result in waste. Therefore, before selecting a mixer, first determine the application environment, such as: wastewater tank, sludge tank, or biological treatment tank; secondly, consider the parameters of the medium, such as: suspended solids content, viscosity, temperature, and pH value; and thirdly, the shape and depth of the tank. The required power of the mixer is determined by the volume, the density of the liquid being mixed, and the mixing depth. Depending on the specific circumstances, one or more mixers may be used.
How to calculate the appropriate model
Mixing and Agitation Type
1. Determine the sludge correction factor for the medium to be mixed according to Figure B1 or Table B1.
2. Determine the tank type correction factor for the mixing tank according to Figure B2 or Table B2.
3. Multiply the power required per cubic meter of clean water (5 W) by the sludge correction factor, then multiply by the tank type correction factor to obtain the actual power required per cubic meter of the medium to be mixed. Multiply this value by the volume of the medium to be mixed to obtain the total power required for the entire mixing tank.
Low-speed plug flow type:
1. Determine the tank shape correction coefficient according to Figure B1 or Table B1.
2. Determine the sludge correction coefficient for the medium to be mixed according to Figure B1 or Ta
ble B2.
3. Determine the power consumption per unit flow rate based on the initial flow velocity y of the mixing medium using Figure B3.
4. Calculate the mixer flow rate by multiplying the initial flow velocity y of the mixing medium by the cross-sectional area formed by the impeller rotation.
5. Multiply the mixer flow rate by the power consumption per unit flow rate, then multiply by the sludge correction coefficient and the tank shape correction coefficient to obtain the power required for the entire tank.
Table B1 Tank Type Correction Factor Table
|
Depth/ Diameter(Width) |
Pool type coefficient |
Depth/ Diameter(Width) |
Pool type coefficient |
|
0.1 |
1.4 |
0.85 |
1.05 |
|
0.15 |
1.31 |
0.9 |
1.08 |
|
0.2 |
1.25 |
0.95 |
1.11 |
|
0.25 |
1.19 |
1 |
1.15 |
|
0.3 |
1.14 |
1.05 |
1.19 |
|
0.35 |
1.1 |
1.1 |
1.25 |
|
0.4 |
1.08 |
1.15 |
1.32 |
|
0.45 |
1.05 |
1.2 |
1.4 |
|
0.5 |
1.04 |
1.25 |
1.48 |
|
0.55 |
1.02 |
1.3 |
1.58 |
|
0.6 |
1.01 |
1.35 |
1.68 |
|
0.65 |
1 |
1.4 |
1.78 |
|
0.7 |
1 |
1.45 |
1.89 |
|
0.75 |
1.01 |
1.5 |
2 |
|
0.8 |
1.03 |
|
|
Table B2 Sludge Correction Factor Table
|
Solid Content Percentage% |
Primary sludge |
Secondary sludge |
Hydrolyzed sludge |
Density g/cm |
|
1.00 |
1 |
1 |
1 |
1.01 |
|
2.00 |
1.15 |
1 |
1 |
1.02 |
|
3.00 |
1.5 |
1.15 |
1.15 |
1.03 |
|
4.00 |
2 |
1.5 |
1.5 |
1.04 |
|
5.00 |
2.6 |
1.9 |
1.9 |
1.05 |
|
6.00 |
3.6 |
2.4 |
2.4 |
1.06 |
|
7.00 |
5.5 |
3.4 |
3.4 |
1.07 |
|
8.00 |
9 |
4.8 |
4.8 |
1.08 |
|
9.00 |
|
6.8 |
6.8 |
1.09 |
|
10.00 |
|
10 |
10 |
1.1 |
|
11.00 |
|
|
|
1.11 |
Mixer operating conditions and multi-position combinations
Compared to traditional shaft mixers, the model QB submersible mixer offers the advantage of generating various flow directions.Its ability to be installed in different positions allows for multiple flow patterns, creating more effective circulation in the tank and eliminating dead zones. The required matching power for the mixer is determined by the tank volume, medium density, viscosity, and the depth of the mixing medium. Depending on specific circumstances, one or multiple mixers may be used.To ensure efficient and energy-saving operation of mixers in different tank types, refer to the following typical installation forms.

Submersible Mixer Flow field diagram