Why does the aeration in some biochemical tanks appear to be boiling vigorously, yet the dissolved oxygen reading remains low?

2026-09-09

Symptom: Bubbles are churning and the water surface is boiling—visually indicating vigorous aeration—yet the dissolved oxygen (DO) meter reads low. This is a common occurrence in wastewater treatment.

Core Principle
Aeration simply injects air into the water; "boiling" indicates a high gas flow rate. However, DO levels depend on the actual amount of oxygen that dissolves into the water body.
No matter how many bubbles there are, if the oxygen escapes to the surface before it can dissolve, the DO level will not rise.

Main Causes
1. Bubbles are too large; poor oxygen mass transfer efficiency
Aging or damaged aeration discs/pipes produce large bubbles. These large bubbles rise rapidly, resulting in very short gas-water contact time; consequently, most of the oxygen escapes the water surface without dissolving. While the water appears to be churning and boiling, actual oxygen utilization is very low.
2. Sludge loading is too high; oxygen consumption rate exceeds oxygen supply rate
High influent COD and ammonia-nitrogen levels drive high microbial populations and activity, causing oxygen to be consumed faster than the aeration system can supply it.
Oxygen is consumed by microorganisms almost instantly as it is supplied. Result: The water boils due to aeration, but DO levels cannot be raised.
Typical scenarios: High-concentration wastewater, shock loading, or excessively high mixed liquor suspended solids (MLSS) concentration.
3. Elevated water temperature
The higher the water temperature, the lower the saturation solubility of oxygen in water. Under identical aeration conditions, the maximum capacity for dissolved oxygen in the water decreases as temperature rises. This phenomenon frequently occurs in biochemical tanks during summer.
4. Uneven mixing within the tank (localized phenomenon)
The DO probe is positioned in a high-oxygen-consumption zone. While the surface churns vigorously, the tank bottom suffers from flow short-circuiting or dead zones. The probe measures a zone of intense oxygen consumption by sludge (showing low DO), even though the surface appears to be boiling.
5. Improper aerator layout
Blower airflow is set high, but the number of aerators is insufficient or aeration is concentrated in specific areas. This results in localized boiling but poor overall tank mixing and insufficient oxygen supply across the system. 6. Dissolved Oxygen (DO) Meter Malfunction (False Low Reading)
Sludge accumulation or biofilm growth on the DO probe membrane hinders oxygen permeation, resulting in an artificially low reading;
Probe calibration failure;
In this case, the meter reading is inaccurate; the system is not actually oxygen-deficient.
7. Presence of Surfactants or Grease/Oil in the Water
Detergents and grease/oil in the wastewater alter the water's surface tension, preventing bubbles from bursting easily and causing excessive foaming; this makes it difficult for oxygen to cross the interface and dissolve into the water.

Simple Troubleshooting Approach
① Calibrate and clean the DO probe first to rule out instrumentation issues;
② Check MLSS and influent COD/ammonia-nitrogen levels to determine if the organic load is excessive;
③ Observe bubble size; if only large bubbles are present, prioritize checking the aerators for damage;
④ Verify the water temperature.