What problems might occur with rotary bar screens during use?
A rotary bar screen consists of a chain of rake teeth assembled from various components. Driven by a motor reducer, the chain of rake teeth moves against the direction of water flow.
When the chain of rake teeth reaches the top of the equipment, the guide wheels and curved rails cause a relative self-cleaning motion between each set of rake teeth, allowing most solid matter to fall off due to gravity. The remaining solids are cleaned by the reverse motion of the sweeper.
The chain of rake teeth, similar to a bar screen in terms of water flow direction, allows for selection of the spacing between the rake teeth mounted on the chain shaft, depending on the operating conditions. After the rake teeth separate the solid suspended matter in the fluid, the water can flow smoothly. The entire process can be continuous or intermittent.
Potential problems during the use of a rotary bar screen:
1. The motor runs normally during operation, but the rake teeth do not rotate.
Cause of failure: Overload of the equipment causing the overload to be cut off.
Solution:
(1) Remove and replace the overload.
(2) Investigate the cause of the equipment overload, mainly checking if there is debris stuck in the rake teeth.
(3) If debris is stuck in the rake tooth chain, clean the debris before starting the machine.
Note: When replacing the overload, refer to the overload assembly diagram.
2. Rake tooth breakage and replacement steps:
(1) Insert the hand crank into the square tenon at the rear of the motor to crank the rake tooth shaft containing the broken rake tooth to the inspection hole, or use the jog switch on the control box to control the motor reducer to move the rake tooth containing the broken rake tooth to the inspection hole.
(2) Remove the handle from the inspection hole side plate.
(3) Use an iron bar to hold the rake tooth chain in place.
(4) Use snap ring pliers to remove the snap rings at both ends of the two rake tooth shafts containing the broken rake tooth.
(5) Pull out the two rake tooth shafts, clean the broken rake tooth, install the new rake tooth, then insert the rake tooth shaft again, and install the snap rings in sequence. (6) Install the inspection hole side plate handle.