Use and maintenance of sludge scraper for high-density sedimentation tank
I. Function
After wastewater enters the sedimentation tank, the clear water flows to the upper layer and exits, while impurities and solid particles remain at the bottom. After a period of time, solid-liquid separation occurs, and the impurities and solid particles settle to the bottom of the tank. A sludge scraper is then used to gather the sludge scattered at the bottom of the tank and collect it in the sludge collection trough in the center of the sedimentation tank.
II. Operating Procedures
(I) Before Operation
(1) Clean debris from the sedimentation tank, working bridge, and walkways;
(2) Check lubrication: The reducer oil level should not exceed the upper limit of the oil gauge or be lower than the lower limit;
(3) Check all connecting parts and bolts of the frame for looseness, and adjust and tighten them as needed;
(II) Use of the Sludge Scraper
(1) Jog the machine to observe whether the sludge scraping direction is correct. Unless otherwise specified, the sludge scraper rotates clockwise; check whether the motors (lifting motor and drive motor) are normal, and whether the oil pump starts simultaneously to supply oil to the reducer; check for abnormal vibration, noise, and overheating of the equipment;
(2) If everything is normal during jogging, start the sludge scraper. The running time and number of runs of the sludge scraper are determined according to the process requirements. Generally, the sludge scraper is started once every 1 hour, and the continuous sludge scraping time is about 3 hours; When the sediment volume is high, the number of sludge scraping cycles can be increased appropriately; the entire working process can be controlled manually and automatically;
(3) The tank must be scraped and discharged regularly to prevent excessive sludge accumulation, which could overload the scraper, affect its normal operation, and in severe cases lead to accidents;
(4) If the sediment is too hard, the tank must be stopped and cleaned before the scraper can be put back into operation;
(5) If any abnormality occurs during the operation of the scraper, the power should be cut off immediately, and the machine should be restarted only after the fault has been repaired and eliminated; see Appendix (Causes and Countermeasures) for details.
(III) Equipment Lubrication
The reducer must be filled with lubricating oil before use. The relevant regulations are as follows:
1. Oil Selection
(1) 220# gear oil is generally used as the lubricating oil in the cycloidal pinwheel reducer at room temperature;
(2) Unclean or corrosive lubricating oil is not allowed to be injected. 2. Lubricating Oil Replacement System
(1) After the initial 150-300 hours of operation of the reducer, add oil. Remove any residual oil during replacement. Subsequent replacements should be made every 3 months for units operating continuously for more than 10 hours per day, and every 6 months for units operating intermittently for less than 10 hours per day.
(2) Before restarting a sludge scraper that has not been used for a long time, the lubricating oil or grease in the reducer must be replaced.
III. Equipment Maintenance
1. External painting and corrosion prevention treatment: Performed after one year of equipment operation, or during routine maintenance.
2. Regularly inspect underwater components, especially the wear of the scraper blades; replace severely worn components promptly.
3. Regularly check the safety and reliability of all electrical components and display instruments.