The selection of submersible flow generators for oxidation ditches needs to take into account the pool structure, hydraulic conditions, media characteristics, and process objectives.
The selection of submersible flow promoters for oxidation ditches requires comprehensive consideration of the tank structure, hydraulic conditions, media characteristics, and process objectives.
I. Clarify Operating Parameters and Application Requirements
Tank Geometric Characteristics
Provide the shape of the oxidation ditch (e.g., racetrack-shaped, circular), effective volume, water depth (typically ≤20m), and liquid level variation range.
For racetrack-shaped oxidation ditches, flow promoters need to be strategically placed in bends and straight sections to avoid short-circuiting or dead zones.
Design Flow Velocity Requirements
Below 0.15 m/s can easily lead to sludge settling;
Above 0.3 m/s, energy consumption is wasteful and may damage the floc structure.
The flow velocity of the mixed liquor in the oxidation ditch should be maintained at 0.15–0.3 m/s.
Process Stage Matching
If used in the anoxic/anaerobic stage, low-shear mixing should be emphasized to protect microbial activity.
If used in conjunction with aerobic aeration, the flow should be coordinated with the aerator layout to improve oxygen mass transfer efficiency.
II. Core Performance Parameter Selection
Thrust and Power Matching
It is recommended to configure equipment with a power of 1.5–3 kW per 1000 m³ of water body, suitable for small and medium-sized oxidation ditches.
For large oxidation ditches (>3000 m³), it is recommended to select a model of 7.5 kW or higher to ensure sufficient thrust coverage.
Reference model naming rules: e.g., QJB5/4-1800/2-63/P indicates 5 kW power and 1800 mm impeller diameter.
Impeller Design and Material Selection
Ordinary wastewater: Polyurethane or fiberglass, with self-cleaning and anti-winding functions;
Highly corrosive environments (e.g., chlorine-containing, low pH): Stainless steel impellers (model suffix "S").
Sweeped banana-shaped impellers are preferred, with a diameter range of 1100–2500 mm and a speed of 36–135 r/min, capable of generating a large-volume flow field.
Material Recommendations:
Motor and Protection Rating
The motor insulation class should be F or higher, with an IP68 protection rating, and a double mechanical seal design suitable for long-term underwater operation.
Equipped with oil chamber leakage detection and winding overheat protection functions to enhance safety.
III. Installation and System Integration Considerations
Installation Method Selection
Guide rod type fixed installation is recommended for easy underwater maintenance and angle adjustment;
The installation depth should ensure an impeller immersion depth ≥900 mm to prevent air intake and cavitation.
The flow direction should be consistent with the mainstream direction of the channel to avoid localized scouring or eddies caused by excessive proximity to the pool wall.
Multiple Units Coordinated Arrangement
In corridor-type oxidation ditches, arrange one unit every 20-30 meters, and alternately adjust the flow angle to form a unified circulation.
During startup, test the phase sequence of each unit to prevent reverse operation due to incorrect power wiring.
Energy Efficiency Optimization Strategy
Integrate with the aeration system for control; the speed can be reduced during low-load periods, achieving energy savings of over 30%.
Prioritize models with bearing life >60,000 hours to reduce maintenance frequency.