For high-concentration wastewater tanks, the selection of hyperboloid agitators requires comprehensive consideration of power, blade diameter, and installation depth. Below is a summary of the selection logic and specific suggestions.

⚙️ Power Selection: Classified by Concentration

Power selection is primarily based on tank volume and power per unit volume (W/m³). For high-concentration wastewater, a safety factor needs to be added.

1. Calculating Base Power

Formula: Base Power (kW) = Tank Volume (m³) × Power per Unit Volume (W/m³) ÷ 1000

Reference values ​​for power per unit volume:

Conventional low to medium concentration wastewater: 3–8 W/m³

Medium to high concentration/easily settling wastewater: 8–15 W/m³

High concentration/high viscosity wastewater: >15 W/m³

2. High Concentration Correction

In addition to the above, multiply by a safety factor of 1.3–1.5 to handle the additional load caused by high concentrations.

Final Power ≈ Base Power × High Concentration Safety Factor

3. Selection Example

Assuming a high-concentration equalization tank with an effective volume of 500 m³:

Base Power: Calculated at 12 W/m³, 500 × 12 ÷ 1000 = 6 kW.

High Concentration Correction: Multiplied by a safety factor of 1.4, 6 × 1.4 ≈ 8.4 kW.

Final Selection: Two 4 kW agitators or one 7.5–9 kW agitator can be selected.

📏 Blade Diameter Selection: Matching Tank Type

The blade diameter (D) must match the tank dimensions to ensure the flow field covers the entire tank and eliminates dead zones.

1. Core Matching Principle

Square/Rectangular Tanks: Recommended Blade Diameter (D) / Tank Width (L) ≈ 0.20 – 0.25.

Circular Pool: Recommended impeller diameter (D) ≈ (0.20 – 0.25) × pool inner diameter.

2. Rule of Thumb and Model Reference

Rule of Thumb: In the absence of precise simulation, D ≈ 0.22 × pool width can be used as a preliminary estimate.

Model Reference: Refer to the table below for preliminary selection; final selection requires power verification.

3. Multi-Unit Arrangement

For large-sized pools, a "multiple small-diameter units" approach should be used instead of a "single large-diameter unit" to avoid dead zones in the flow field and improve mixing efficiency.

📐 Installation Depth: Optimizing Flow Field Distribution

Installation depth directly affects flow field morphology, anti-deposition effect, and energy consumption. The distance (H) from the impeller centerline to the pool bottom is a key parameter.

1. Balancing Anti-Deposition and Anti-Abrasion

General Range: H ≈ (0.20 – 0.30) × effective water depth (Hw).

1. **Low Limitations:** To prevent wear and sludge ingress, the impeller's lowest point should generally be at least 300–500 mm from the tank bottom.

2. **Recommendations for Different Tank Depths:**

Shallow Tanks (Hw ≤ 4 m): H ≈ 0.25 × Hw, balancing overall circulation and bottom sediment prevention.

Medium-Deep Tanks (Hw = 4–8 m): H ≈ 0.20 × Hw, allowing for a slightly lower installation height to enhance bottom agitation.

Deep Tanks (Hw > 8 m): It is recommended to arrange agitators in layers, rather than relying solely on a single deep-mounted device.

3. **Special Considerations for High Concentration Conditions:**

High Concentration/Easy Settling: The H value can be appropriately reduced, but the impeller's lowest point must be at least 300 mm from the tank bottom.

Containing Large Particles/Fibers: To avoid clogging, the H value should not be too low; if necessary, it can be increased to 0.30 × Hw or higher.


**Containing Large Particles/Fibers:** To avoid clogging, the H value should not be too low; it can be increased to 0.30 × Hw or higher if necessary. 💡 Three-Step Selection Method Summary

**Establish Power:** Calculate the base power based on the pool volume and high concentration characteristics, and multiply by a safety factor of 1.3–1.5.

**Select Impeller Diameter:** Based on the pool width, initially select the impeller diameter according to the principle of D ≈ (0.20–0.25) × pool width, and refer to standard models.

**Establish Depth:** Based on the effective water depth, determine the installation height according to the principle of H ≈ (0.20–0.30) × Hw, and ensure that the lowest point of the impeller is not less than 300 mm from the bottom of the pool.

**Note:** The above are rules of thumb for engineering. For critical or complex operating conditions, it is recommended to combine CFD fluid simulation for precise design.