Precautions for operating PAM dosing devices
PAM Dosing System Operation
1. The dosing system has an independent reagent dosing device, agitator, and dosing pump.
2. Add the reagent to the dosing hopper and start the dosing device and water inlet system.
3. Turn on the agitator.
4. Before starting dosing, ensure the pipeline is unobstructed.
5. After the reagent enters the storage tank, start the dosing pump. Once the speed is normal, slowly open the ball valve at the pump outlet, and then adjust the pump flow rate to the design requirements.
PAM Dosing System Maintenance
1. All pipelines and valves are UPVC ball valves. Therefore, opening and closing valves should be done slowly and gently. Do not force them, as this may cause pipeline and valve breakage.
2. When the dosing system is operating normally, the cover should be firmly closed to prevent foreign objects from entering the reagent tank.
3. Keep the dosing device clean. Do not spill solid powdered chemicals on the device, and never allow them to accumulate on the gate handle, causing scale buildup and preventing rotation. Therefore, frequent flushing is essential for civilized production.
4. Chemicals should be neatly stacked, elevated to avoid direct contact with the ground and prevent moisture absorption. Chemicals not currently in use should not be opened. Once opened, chemicals should be used as soon as possible. Chemicals that have formed large clumps due to moisture should not be used.
5. Ensure the quality of purchased chemicals; there should be no excessive insoluble sediment.
6. Clean the chemical tank regularly. Every month or quarter, the chemical tank should be emptied and cleaned.
7. When the dosing device is not used for an extended period, drain the chemicals and flush it thoroughly. Simultaneously, drain the liquid from the pump and flush it with clean water.
8. Regularly check the oil level in the agitator's reducer. If the oil level is below the specified level, replenish the reducer with lithium-based grease promptly. (Replace every six months)
9. Regularly check the grounding of electrical equipment to prevent the grounding wire from becoming loose.
10. During motor operation, frequently check the motor's operation and heat generation. If abnormal noises or excessive heat are detected, stop the machine immediately and troubleshoot the problem.