How to determine if the bubbles in a biochemical tank are too large.
I
I. Visual Assessment (Fastest on-site method)
1. Bubble Characteristics
Normal, high-quality aeration: Fine bubbles creating a milky-white mist; most bubble diameters range from 1–3 mm; slow ascent; fine ripples on the water surface; no large bubbles bursting.
Oversized bubbles: Bubble diameters >5 mm; individual large bubbles clearly visible to the naked eye; rapid ascent; bursting with a "pop" upon reaching the surface, causing splashes; only sporadic foam on the surface, lacking a uniform milky-white air-water mixture layer.
Extreme cases: Fist-sized bubbles surging upward in bursts; violent localized turbulence resembling boiling, yet the gas-liquid contact time is very short.
2. Surface Characteristics
Large bubbles: Foam is sparse and fragile, dissipating quickly; violent localized turbulence leads to uneven aeration across the tank.
Small bubbles: A uniform thin layer of foam floats on the surface; foam dissipates slowly; overall agitation is gentle.
II. Assessment Based on Operational Indicators (Crucial; avoid relying solely on visual appearance)
1. Dissolved Oxygen (DO) Comparison
Phenomenon: Violent surface turbulence and many large bubbles, yet DO remains low—this indicates bubbles are too large.
Principle: Large bubbles have a small specific surface area, making it difficult for oxygen to dissolve into the water; gas escapes directly from the surface quickly, resulting in low oxygen utilization efficiency and wasted blower energy.
2. Sludge Condition
Oversized bubbles → High shear force; easily breaks apart activated sludge flocs; effluent becomes turbid; Suspended Solids (SS) levels rise.
Bubbles too small (excessive micro-bubbles) → May cause sludge to adhere to bubbles, leading to floating sludge.
3. Tracing Aerator Condition
Common causes of large bubbles: Damaged or torn aerator membranes, detached clips, or pipeline leaks; cracked aeration discs allowing compressed air to rush out directly without being sheared into micro-bubbles. III. Simple Comparison Criteria
1、Excessively Large Bubbles
Bubble diameter ≥ 5 mm; individual bubbles are clearly visible to the naked eye. They rise rapidly, instantly breaking the water surface. Oxygen transfer efficiency is poor, and oxygen utilization is low. The water surface shows large bubbles bursting and splashing; there is a risk of breaking apart sludge flocs and causing effluent turbidity.
2、Suitable Micro-bubbles
Bubble diameter is 1–3 mm; they appear as a fine, mist-like cloud. They rise slowly. Oxygen transfer efficiency is high, and oxygen utilization is excellent. The water surface displays uniform, fine ripples. Agitation is gentle, preserving sludge floc integrity.
IV. Practical On-site Method
You can use a transparent beaker to collect a sample from below the liquid surface of the biochemical tank for observation:
If distinct, large bubbles are seen rising rapidly → Bubbles are too large;
If the water appears milky white and the bubbles are so fine that individual ones are barely visible → Bubble condition is optimal.