Routine maintenance of Submersible Mixers mainly includes regular checks of operating status, lubrication system, sealing performance, and electrical safety. The core principle is preventative maintenance to extend equipment life and ensure effective wastewater treatment.

Based on multiple technical documents and operational experience, the following are systematic points for routine maintenance:

I. Routine Inspection (Daily or before each operation)

This is the first line of defense against potential faults and should be the focus:

Operating Status

Listen for abnormal noises (such as metallic friction or impact sounds). A normal sound should be a steady flow of water.

Observe for excessive vibration. This can be initially assessed by touch. Severe vibration may indicate impeller imbalance or bearing damage.

Current and Voltage Monitoring

Low current → May indicate idling or impeller detachment;

High current → Excessive load, entanglement, or mechanical failure.

Check if the ammeter in the control cabinet is within the rated range:

Leakage Observation

Check for oil stains floating on the water surface, which may indicate leakage in the gearbox or mechanical seal.

**Cable and Connector Inspection**

Inspect cables for damage, aging, or bending under stress.

Ensure cable clamps are secure; never use cable lifting equipment.

**II. Regular Maintenance (Every 3-6 Months)**

In addition to routine inspections, more thorough shutdown checks and maintenance are required:

**Lubricating Oil Change**

Change the oil chamber lubricating oil every 6 months. 32# machine oil is recommended.

When changing the oil, be aware that there may be residual pressure on the oil plug; unscrew it slowly to prevent splashing.

If the oil is milky white (emulsified), it indicates water ingress; immediately check and replace the mechanical seal.

**Mechanical Seal Inspection**

This is a critical component for preventing water ingress into the motor. Disassembly and assembly must be performed in a clean environment using pure lubricating oil.

Inspect the stationary ring sealing surface for wear and cracks; replace the entire sealing assembly if necessary.

Bearing Lubrication and Replacement

Replace the grease during major overhauls, filling the bearing cavity to 1/3 to 1/2 full.

High-temperature calcium-sodium based grease is recommended, as it is heat-resistant and has good oxidation resistance.

Fastener Inspection

Check the impeller locking nut, mounting bolts, and guide rod connectors for looseness.

Pay special attention to the safety of lifting devices and fasteners to prevent them from falling off during operation.

Impeller and Casing Cleaning

After removing the equipment, remove fibers, plastic, and other entangled materials from the impeller.

Inspect the impeller for corrosion, cracks, or deformation; replace it if the gap exceeds 2mm.

III. Annual and Long-Term Maintenance

Insulation Testing

Use a megohmmeter to test the insulation resistance of the motor windings to ground; it should be ≥1MΩ.

Degradation of insulation may lead to leakage, endangering personal safety.

Long-Term Inactivity Handling

If the equipment is idle for more than 15 days, it is recommended to run it for 30 minutes every 15 days to prevent dry friction of the sealing surfaces.

For long-term storage, it should be removed, cleaned, stored in a dry and ventilated place, and coated with anti-rust oil.

Major Overhaul Cycle (Every 2-5 Years)

Replace bearings, O-rings, cables, and other easily worn parts.

Clean the gearbox and check the gear meshing.

IV. Safety Operation Red Lines

✅ Power Off Operation: Power must be disconnected and locked before any maintenance to prevent accidental start-up.

✅ Dry Operation Strictly Prohibited: The equipment must not be started when it is not submerged; otherwise, the motor may burn out within minutes.

✅ Unauthorized Disassembly and Repair Prohibited: If the cause of the malfunction is unknown, personnel should be called to handle it to avoid further damage.